Gas Detector Natural Gas LPG Methane CH4 Leakage Monitor for Home Office
Gas Detector Natural Gas LPG Monitor for Home Office introduction
Gas Detector Natural Gas LPG Monitor for Home Office is a smart combustible gas detector with microprocessor control. This meter will make a sound with the build - in siren when the combustible gas leakage. This detector adopts semiconductor sensor which is stable and reliable.
Gas Detector Natural Gas LPG Monitor for Home Office keep the place safe from the threats of combustible gas( Such as liquefied petroleum gas, natural gas, methane etc.)
Product features.
** High reliable semiconductor sensor
** Power supply from AC90V - 240 V or 9 V rechargeable battery
** intelligent microprocessor control
Product appearance.
Operation instruction.
1. First start
Connect Gas Detector Natural Gas LPG Monitor for Home Office to 90V - 240V power. The green indicator light will light up. As the same time, the red light flashing, then the detector will go to the normal work situation after three minutes preheating.
2. Alarm
When the gas concentration is over 2,500 part per million, the buzzer sound will make a continue sound as "Di-Di-Di" and the red indication light will flash at the same time. At this moment, please close the gas valve and open the door to clear the gas and inform the professional to check. If it is false alarm, please check whether the installation place is suitable or not.
Installation
Please confirm the induced gas is heavier than air or lighter than air. the gas is heavier than air : LPG etc. the gas is lighter than air : natural gas, marsh gas and etc.
Choosing the suitable position to install Gas Detector Natural Gas LPG Monitor for Home Office according to the gas specific gravity. Detecting the gas heavier than air. Installation height from floor 0.3 - 1 metre semi-diameter to gas source less than 1.5 metre : Detecting the gas lighter than air, installation height from ceiling 0.3 - 1.0 metre semi-diameter to gas source less than 1.5 metre.
Avoid installing Gas Detector Natural Gas LPG Monitor for Home Office close to the following sources of interference : direct air flow from vents, fans, doors, windows, sources of steam, oil vapor, etc.
All wires installation must accord with the national and local effective laws and criteria. The wires must have the suitable size and colorful marks for avoiding connecting error. and unsuitable connection of wires will result in the alarm error while gas leaking happened.
Technical Parameter
1. AV Voltage : AV 9V-240V, 50 - 60 Hz
2. Battery Voltage : 9V rechargeable battery(Optional)
3. Working Temperature : 0 - 50 celcius
4. Environment humidity : 10 - 95 percent
5. Alarm density : 2,500 part per million(+/- 1,500 part per million)
6. Alarm time : Keep alarming after over 2,500 part per million
7. size of Gas Detector Natural Gas LPG Monitor for Home Office : 112 x 73 x 42 millimetre.
Notice :
1. The gas detector is easy to be effected by the sharp pounding and shock in transit or installation, lead to not work.
2. This is a combustible gas detector. So this meter can not detect the poisonous gas such as carbonmonoxide.
3. Scheduled maintenance : surface cleaning per month, specialist inspection per half year.
4. Don't use the detergent to clean the gas detector, By doing this will damage the meter.
5. Don't Spray any Sprays such as air freshener, hair spray, etc.
6. Gas Detector Natural Gas LPG Monitor for Home Office is only used to reduce the accident, make sure everytime. Except use our detector in right way, please also pay more attention in your daily life and strengthen safety and security conciousness.
Gas Detector Natural Gas LPG Monitor for Home Office available at these seller.
วันศุกร์ที่ 3 กุมภาพันธ์ พ.ศ. 2560
Ceiling Mounted LPG Natural Gas H2 Leakage Gas Leakage Alarm
Ceiling Mounted LPG Natural Gas H2 Leakage Gas Leakage Alarm
Specification
- Superior sensor are adopted for this Ceiling
Mounted LPG Natural Gas H2 Leakage Gas
Leakage Alarm . The ignitable leakage
combustible gas can be detectored by the
method of light also sound alarm and driver
the valve to remove the danger. Not only
that Ceiling Mounted LPG Natural Gas H2
Leakage Gas Leakage Alarm can be used as
independent family alarm equipment, and also
can be used as front detector of alarm system.
- Power source Use simple 12 VDC.
- Sensitivity : ten percent of LEL
(Lower explosive level).
- Power consumption : 1.7 Watt.
- Operation Temperature : minus ten to fifty degree celcius.
- Ambient Humidity : Less than ninety-five relative humidity.
- Horn Level : eighty-five decibels.
- Weight of this meter : 270 grams.
- Type of Combustible Gas sensed :
+ LPG(Butane, Propane) used in normal and mini gas bottles.
+ Combustible gas from piping system(City gas) and natural gas(Methane)
Applications.
- Mounted Ceiling Mounted LPG Natural
Gas H2 Leakage Gas Leakage Alarm on the
wall or ceiling, about thirty centimeter above
the ground for LPG or about thirty centimeter
below the ceiling for coal gas and natural gas
use.
- Ventilation hole showed as sketch map
should be installed down.
- After power - on, the relay output stop,
the yellow indication shall be flashed for
preheating of sensor which is not the normal
operation of detection ;
- After three to four minutes, the yellow
indicator shall be stopped flash and the relay
output shall be closed for normal operation of
detection ;
- When the combustible gas is detected, the
red light shall be flashed with "Di-Di-Di"
alarm sound, after 10's the relay output is open
until the combustible gas fade out.
- If the sensor is invalid, the red indicator
will be light and with "Di-Di-Di" sound
continuous. Power the switch off wait for 30
second and switch on again.
Attention :
- Install Ceiling Mounted LPG Natural Gas
H2 Leakage Gas Leakage Alarm firmly to
avoid impact and drop;
- Do not let dust and oil block the
ventilation slots;
- Do not install product near hot, humid
and oiling sources. Do not install Ceiling
Mounted LPG Natural Gas H2 Leakage Gas
Leakage Alarm near window or fan, where
combustible gas can be quickly disappeared.
- Monthly checking if Ceiling Mounted
LPG Natural Gas H2 Leakage Gas Leakage
Alarm can work well by pushing a little
combustible gas from a cigar lighter near the
ventilation slots.
Power supply
Ceiling Mounted LPG Natural Gas H2 Leakage
Gas Leakage Alarm Available at this seller.
Specification
- Superior sensor are adopted for this Ceiling
Mounted LPG Natural Gas H2 Leakage Gas
Leakage Alarm . The ignitable leakage
combustible gas can be detectored by the
method of light also sound alarm and driver
the valve to remove the danger. Not only
that Ceiling Mounted LPG Natural Gas H2
Leakage Gas Leakage Alarm can be used as
independent family alarm equipment, and also
can be used as front detector of alarm system.
- Power source Use simple 12 VDC.
- Sensitivity : ten percent of LEL
(Lower explosive level).
- Power consumption : 1.7 Watt.
- Operation Temperature : minus ten to fifty degree celcius.
- Ambient Humidity : Less than ninety-five relative humidity.
- Horn Level : eighty-five decibels.
- Weight of this meter : 270 grams.
- Type of Combustible Gas sensed :
+ LPG(Butane, Propane) used in normal and mini gas bottles.
+ Combustible gas from piping system(City gas) and natural gas(Methane)
Applications.
- Mounted Ceiling Mounted LPG Natural
Gas H2 Leakage Gas Leakage Alarm on the
wall or ceiling, about thirty centimeter above
the ground for LPG or about thirty centimeter
below the ceiling for coal gas and natural gas
use.
- Ventilation hole showed as sketch map
should be installed down.
- After power - on, the relay output stop,
the yellow indication shall be flashed for
preheating of sensor which is not the normal
operation of detection ;
- After three to four minutes, the yellow
indicator shall be stopped flash and the relay
output shall be closed for normal operation of
detection ;
- When the combustible gas is detected, the
red light shall be flashed with "Di-Di-Di"
alarm sound, after 10's the relay output is open
until the combustible gas fade out.
- If the sensor is invalid, the red indicator
will be light and with "Di-Di-Di" sound
continuous. Power the switch off wait for 30
second and switch on again.
Attention :
- Install Ceiling Mounted LPG Natural Gas
H2 Leakage Gas Leakage Alarm firmly to
avoid impact and drop;
- Do not let dust and oil block the
ventilation slots;
- Do not install product near hot, humid
and oiling sources. Do not install Ceiling
Mounted LPG Natural Gas H2 Leakage Gas
Leakage Alarm near window or fan, where
combustible gas can be quickly disappeared.
- Monthly checking if Ceiling Mounted
LPG Natural Gas H2 Leakage Gas Leakage
Alarm can work well by pushing a little
combustible gas from a cigar lighter near the
ventilation slots.
How to do when you are alarmed ?
- Carefully remove all children and not
related people from that area.
- Turn off all gas valve and gas cylinder,
open all doors and windows for the sake of
good ventilation.
- Do not use electrical equipments, not
turning any contractors. Do not let electric
sparks appear.
- Waiting until the equipment stop alarm
then checking the gas system or phone to gas
supplier to verify it. Or else the meter not stop
alarm turn the meter off by switch off remove
people and recheck this area carefully.
- If there is an auto-valve, it will
auto-close the gas pipe. After finalizing all
errors of gas system, reset the valve by pulling
out the red button.
Power supply
110V AC to 12V DC Low Voltage Output
Ceiling Mounted LPG Natural Gas H2 Leakage
Gas Leakage Alarm Available at this seller.
สมัครสมาชิก: