วันอังคารที่ 14 กรกฎาคม พ.ศ. 2558

Salt Check Tester model SB-2000Pro Manual(With Pictures)

Specification of SB-2000Pro

      Model : Gimisanggung  Pro(SB-2000Pro)
    Measuring Method : Intelligent automated measurement
    Measuring Range : 0.01 to 10.0 percent

    A.T.C: 0 degree celcius - 98 degree celcius(0.01 - 5.0 percent)
                0 degree celcius - 80 degree celcius(5.1 - 8.0 percent)
                0 degree celcius - 40 degree celcius(8.1 - 10.0 percent)

    Resolution : 0.01 percent(0.01 - 2.99 percent) 
                          0.1 percent(3.0 - 10.0 percent)

    Accuracy : 0.01 - 2.00 percent(+/- 0.1 percent)
                     2.01 - 3.00 percent(+/- 0.2 percent)
                     3.1 - 5.0 percent(+/- 0.3 percent)
                     5.1 - 10.0 percent(+/- 0.5 percent)

    Auto Shut-Off : After 30 seconds, Power-saving features.
    Temperature Compensation : Automated(ATC) to 25 degree celcius
    Display : LCD Screen
    Automatic Power On : Power turns on automatically if the object is sensed
    Completion Function : Data value is fixed automatically after measurement
    Power Source : 2 x 1.5V bateries (Include AAA type batteries)
    Housing : Daily life waterproof
    Dimensions of this meter : 25.0 x 24.6 x 170(mm.)
    Weight : 64.8 grams(Include batteries)


LCD Display



1. Salinity value

2. Battery status indicator

3. Icon "measuring salinity"

4. Icon "Salinity measurement completed"

5. Icon "Sensor cleaning"

6. Unit for measuring Salinity(%)


Name of each component




How to Change the Battery

    Change Battery when LCD display battery replace indication Change battery before to "Lo" sign in display which indicates unable to measure due to low battery level.




1. Use a coin to turn the battery cover 90 degrees counterclockwise.

2. Remove the batteries inside.

3. Get two AAA batteries. The + side should face towards the top lid.

4. Use a coin to rotate 90 degrees clockwise in order seal the battery lid.

How to use or How to measure by SB-2000Pro.


1. Before usage, be sure to clean the sensor tip with a soft cloth.

2. Stir the testing liquid at least once before inserting the sensor tip.

** After placing the sensor tip into a sample of soup to be tested, be sure to not touch any solid food matter inside the soup.(Contact with solid food matter will likely cause an error in salinity reading)


3. When the reading is completed, the sensor will vibrate are "READ" indicate on the screen. At this point, remove the sensor and read the measurement.


4. If any of the tested liquid is left on the sensor, a measurement error can occur, causing the sensor to continuously flash. When this occurs, clean the sensor with a soft, moistened tissue for an accurate reading.


** When the indicator flashes "CLEAN", the sensor's function to automatically test for salinity will not work temporarily.(When this occurs, please clean the sensor with a soft moistened tissue).



5. After using SB-2000Pro. Be sure to clean with a soft, moistened tissue; rinse and wipe with a tissue.

** Caution in measuring


     Like the diagram to the right, be sure to submerge the Digital Salt Tester at least 0.5 inch(or 1 cm.) away from the surface bottom.




     Be sure to plunge at least half of the sensor's tip.(Be sure to not touch any solid food matter)




** Caution in handling

     When testing a soup that is being boiled, the measurement can be inaccurate because of the continually changing temperature.

      Putting SB-2000Pro in dishwasher will likely cause damage. Do not plunge the Digital Salt tester into water.

      Please be aware that the digital Salt tester can malfunction due to exposure to heavy shocks and water damage.





















SB-2000Pro Available at this seller.

วันจันทร์ที่ 13 กรกฎาคม พ.ศ. 2558

CDN TT1 Thermometer manual

Digital Tea Thermometer and Timer 
Model CDN TT1

     Fourteen – Two hundred and twelve degree fahrenheit or minus ten to one hundred degree celsius Get Professional Results Every time.

         Designed for precision, CDN TT1 is perfect for eighteen types of loose, ball or bagged tea. You can use this CDN TT1 thermometer to determine the exact steeping temperature of the water. Then you can easily choose from eight tea strengths. Simply choose between Fahrenheit and Celsius.

       You can choose the type of tea and the strength desired. CDN TT1 thermometer has been pre programmed with eighteen tea choices. The tea types include settings such as Brozh, black, booln, chia, China, dajel, earl grey, fruit, gooln, green, herbal, jadeo, japan, jasmine, pooch, peuht, roott and white. The perfect steeping time is displayed with the water temperature until the audio/visual alarm sounds.

Tea Tips : The size of the tea leaf has an effect on the volume of tea. The general rule of one slighty heaped teaspoon of tea per cup should be adjusted to the weight of 0.06 ounce / 1.75 grams.

Please note that : Remove Sticker from display before use. Clean

the Thermometer stem before  each use is important. Very 

important Do not use CDN TT1 thermometer in microwave.





วันอาทิตย์ที่ 12 กรกฎาคม พ.ศ. 2558

Wood Moisture Content Rate

       Moisture wood moisture meter is one of instrument use for measure the amount of water in the substance. This information can be used to determine whether the material is ready for use or not. Unexpected more or less moisture in substance is need for further inspection.

        Wood product also paper product are very very sensitive to humidity. Their physical properties are strongly dependent on moisture content. 


Logs with new cut possible have a moisture content (MC) more than 80 percent, depending on what species are. 

Wood Moisture Content Rate(WMCR)

      What is Wood Moisture Content Rate? 

            In many country, the rate of water weight contained in the wood to the weight of absolute dried wood is defined as WMCR or so call wood moisture content rate. The WMCR varies with the different tree and different part of a tree, for instant the red pine's WMCR at the core is 70 percent and 200 percent at the edge. The same tree from different region also makes the WMCR different. 

What WMCR is suitable for deep process?

       Under certain environment for a long time, The WMCR comes to a steady value which is refered to as balance WMCR under the environment. When the WMCR is above the value, the wood will gives off the moisture and contract, but if WMCR less than the value, it will take in the moisture and inflate. High WMCR of the wood may result in loose glue connection and distortion after process. Different region and different purpose requires different on WMCR of the wood. The natural balance WMCR of the wood is between 7 percent to 18 percent which has become the check point in wood products manufacturing. Additionally, you can measure the WMCR of given stardard wood, then compare it the WMCR of the wood to be tested.

What is balance WMCR?

     Under a given air condition, the final WMCR or say steady WMCR is refered to as balance WMCR(Steady water content state). The year average WMCR of some country is shown as table 

How many method are there to measure the WMCR?

       There are drying method, electrical method, Carbonization method, tritation method and humidity method for measuring the WMCR. Drying method and electrical method are normal adopted in production process. The drying method that calculating the weights of a wood before and after being absolute dried has high precision but takes considerable long time and complicated, it is usually adopted in laboratory. While the electric method base on some electric properties of a given wood that varying with the water content in the wood is being adopted to measure the WMCR in mass production this method has lower precision compared with the drying method, but still be able to meet the normal production process requirements.

How to measure the WMCR of a wood exactly with the unit?

    As shown below, Just follow the following rules to measure on a newly cut wood or the latest texture.

1. cut the wood in direction vertical to the horizontal texture of the wood.



2. Do not measure with the skin of the tree.


3. Do not measure along the round texture side.


4. Do not measure along the straight texture.




       Why are there different results measured by different manufacturers of diffenrent type of moisture meters? The electrical properties of a given wood varies with the trees, temperature and regions, and most products can not set every modified value for each tree, only one certain tree and temperature can be used as modification ground, this is the reason that different results came out.

Will Low battery affect the measurement result?
       When the battery power is less than 70 to 80 percent the measurement result becomes decrease. For instant, at normal voltage the moisture meter measured reading is 14 percent, but when the battery power is less than 70 percent the measured reading might show 11 percent or even less on measuring the same wood. So once moisture meter the low battery indication displayed on the LCD, the best thing to do is replace a new battery to ensure the accuracy of measurement.

วันอาทิตย์ที่ 21 มิถุนายน พ.ศ. 2558

HawkEye DT1B DepthTrax 1B

HawkEye DT1B DepthTrax 1B


  • Hawkeye DT1B DepthTrax 1B Combination Transom Mount / Glue-In-Hull Transducer

  • Hawkeye DT1B provide user precise depth readings (either feet or meters) from 2.5 to 200 feet at speeds up to 63 miles per hour.

  • Hawkeye DT1B DepthTrax 1B Incorporates an advanced three-stage depth alarm warning system with programmable shallow and deep water alarms; "Keel-Offset" function allows readings to be adjusted for vessel draft.

  • Hawkeye DT1B DepthTrax 1B give user a Easy touch, algorithmic, digital programming; waterproof front face, and clear large illuminated display.

  • Display dimensions : 1.65 x 0.85 inches (Width x Height)








HawkEye DT1B DepthTrax 1B Available at amzn.to/2SgEWp3

Radiation detect Watch

Radiation Detect Watch











Radiation Detect Watch description

A Radiation Detect Watch Leather Strap with a sleek also stylish combination of gamma dosimeter. This Radiation Detect Watch is a Swiss-made watch. This watch has Geiger-Muller tube that acts as its sensor able to detects and measure gamma-radiation and convert it to Dose Equivalent Rate (DER) and Dose Equivalent (DE). 